11.2.19
Command SM
<id>SM<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Type return value:
Return value:
Value range:
Initial value:
Note:
After resetting parameter 2 ("FO2") to parameter 0 ("FO0"), the encoder must
be restarted! A restart can be carried out with the "RS2" command (pass-
word level "User" / KY234).
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
Power saving mode
reading / writing
The command enables reading and setting the power saving
mode.
unsigned integer
0: all modules active
1: µC and interfaces disabled
(frequency output active, when FO = 7)
After activation of power-saving mode the sensor cannot be op-
erated via the serial interface after approx. 30sec. After a restart
the interface is active for 30 sec.
Parameter HT0 should be set in the power-saving mode.
2: reserved
unsigned integer
see parameter
0...2
0
021814/03/21
Page 49 of 86