Command Br; Command Bt - Thies CLIMA First Class Advanced X Instructions For Use Manual

Wind transmitter
Table of Contents

Advertisement

11.2.1 Command BR

<id>BR<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Type return value:
Return value:
Value range:
Initial value:

11.2.2 Command BT

<id>BT<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Type return value:
Return value:
Value range:
Initial value:
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
Setting the baud rate
reading / writing
With the command BR, the desired baud rate is set.
unsigned integer
Parameter
12
24
48
96
192
384
576
unsigned integer
see parameter
12 / 24 / 48 / 96 / 192 / 384 / 576
96
Bus termination
reading / writing
With the command, the RS485 interface can be interconnected
with a 120 Ohm wave terminating resistor (bus termination).
unsigned integer
0: Termination off
1: Termination enabled (120 Ohm)
unsigned integer
see parameter
0 / 1
0
Description
1200baud
2400baud
4800baud
9600baud
19200baud
38400baud
57600baud
021814/03/21
Page 36 of 86