11.2.7 Command HP

<id>HP<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Note:
Disabled the heater of pressure and acceleration sensors
has no influence on the IEC conformity. Furthermore, ex-
ist the classification according to IEC.
Type return value:
Return value:
Value range:
Initial value:

11.2.8 Command HT

<id>HT<parameter><CR>
Access:
Description:
Note:
With this command, the galvanically separate housing
heater is activated at the contacts 7/8 or deactivated.
Parameter type:
Parameter:
Type return value:
Return value:
Value range:
Initial value:
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
Reference variable Sensor temperature control unit.
reading / writing
The pressure and acceleration sensors are thermally coupled
and can be heated. The "HP" command sets the setpoint for the
Sensor temperature controller.
The information is given in °C with one decimal place.
unsigned integer
0...600: Reference variable 0...60.0°C
65535: Heating of pressure and acceleration sensors is
switched off
unsigned integer
see parameter
0...600 / 65535
500
Mode of the housing heater control.
reading / writing
The command sets the mode for the housing heater
(only possible at 4.3352.00.40x)
unsigned integer
0: Heater off
1: Heater on (controlled to ~ 4°C)
unsigned integer
see parameter
0...1
1
021814/03/21
Page 39 of 86