11.2.3 Command CI
<id>CI<parameter><CR>
Access:
Description:
Note:
If the identification number (ID) is bigger than 98, it is au-
tomatically set to 0 when switching over into the THIES in-
terpreter!
Note:
If the identification number (ID) equals 0, a switch-over
into the MODBUS-RTU interpreter is not possible!
Parameter description:
Value range:
Initial value:
11.2.4 Command CK
<id>CK<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Type return value:
Return value:
Value range:
Initial value:
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
Selection of the command interpreter.
reading / writing
With the command CI, the desired command interpreter is set.
Parameter
0
1
0 to 1
0/1 depending on device version
0 for 4.3352.x0.400, 1 for 4.3352.x0.401
Password for writing access to calibration tables.
writing
With the command, the password is set for writing access to the
calibration tables (see command WC). The password must be
set 2 consecutive times within a time frame of 60 seconds.
If the password has been changed once, the current password
must be set before changing it again.
unsigned integer
1...4294967295
unsigned integer
see parameter
1...4294967295
137
Description
THIES
MODBUS RTU
021814/03/21
Page 37 of 86