Command Rc - Thies CLIMA First Class Advanced X Instructions For Use Manual

Wind transmitter
Table of Contents

Advertisement

11.2.15

Command RC

<id>RC<parameter><CR>
Access:
Description:
Parameter type:
Parameter:
Type return value:
Return value:
Transfer
parame-
1...10
© Adolf Thies GmbH & Co. KG · Hauptstraße 76 · 37083 Göttingen · Germany
Phone +49 551 79001-0 · Fax +49 551 79001-65 · info@thiesclima.com · www.thiesclima.com
Read calibration table.
reading
With the command, the table indicated in the parameter is read.
The value returned by the command RC depends on the pa-
rameter:
unsigned integer
Parame-
ter
Table (0 ... 10)
0 ... 10
0: Standard curve
1: Table 1
2: Table 2
...
9: Table 9
10: Table 10
Time stamp (date/time) of all tables
99
(empty tables, i.e. unfilled tables give the following
time stamp: tt;2010.00.00;00:00:00;)
Character string
ASCII representation
ter
<STX>
sssss[1];iiiii[1];
sssss[2];iiiii[1];
...
sssss[32];iiiii[32];
xxxxxxxxxx;
uuuuuuuuuuuuuuuu;
YYYY.MM.DD;HH:NN:SS
<ETX>
Description
Return value
Description
32 sampling points in the table
+ calibration certificate number
+ date/time
sssss: Target value in
0.01[m/s]
iiiii: Actual value in 0.01[m/s]
xxxxxxxxxx: Calibration certifi-
cate number
uuuuuuuuuuuuuuu: User string
with 16 characters
YYYY: Year
MM: Month
DD: Day
HH: Hour
NN: Minute
SS: Second
021814/03/21
Page 45 of 86