System-Stopped Maintenance; Removing A Power Supply Unit - Fujitsu M10-4 Service Manual

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
10.3.4

System-stopped maintenance

1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF>   showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Stop the entire system.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
For a single-chassis configuration, you do not have to release the chassis.
Proceed to step 7.
XSCF>   replacefru
For details, see
system."
7.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
10.4

Removing a Power Supply Unit

This section describes the procedure for removing a power supply unit. Enable the
removal of the power supply unit before attempting to remove it. For details, see
"10.3 Enabling the Removal of a Power Supply
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.4 Stopping the Entire
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
Chapter 10 Maintaining the Power Supply Units
Configuration."
System."
cord."
Unit."
205

Advertisement

Table of Contents
loading

This manual is also suitable for:

M10-4sSparc m10-4Sparc m10-4s

Table of Contents