Figure 17-3 Pulling out the XSCF unit
4.
Support the XSCF unit from below with one hand and then remove it carefully.
Note - Place the removed XSCF unit on a grounded antistatic ESD mat.
17.5
Installing the XSCF Unit
This section describes the procedure for installing the XSCF unit.
Note - When mounting a XSCF unit, check the connectors on both of the chassis and
XSCF unit beforehand to confirm that no pin is bent and all the pins are neatly
arranged in lines. If an XSCF unit is mounted with a bent pin in a connector, the
chassis or XSCF unit may be damaged. Also, carefully proceed with the work to
prevent any pin from being bent.
1.
Carefully insert the XSCF unit into the chassis.
2.
Raise the right and left levers and then tighten the two screws.
3.
Reconnect all the cables to the XSCF unit.
Chapter 17 Maintaining the XSCF Unit of the Crossbar Box
311