XSCF> showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Power off the physical partition requiring maintenance.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF> replacefru
For details, see
system."
7.
Remove all the power cords from the PSU backplane unit of the chassis
requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
9.3.2
System-stopped maintenance
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Stop the entire system.
For details, see
6.
Execute the replacefru command to release the chassis requiring maintenance
from the system.
XSCF> replacefru