Fujitsu M10-4 Service Manual page 221

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

3.
Execute the diagxbu command to diagnose the crossbar cables.
Diagnosis is performed when the system board of the chassis connected with the
crossbar cables is not incorporated into the physical partition, or when the
physical partition into which the chassis is incorporated is powered off.
 
The example below specifies the following:
00: BB-ID of the chassis to start the diagnosis
01: BB-ID of the destination where the chassis to start the diagnosis is connected
(You can specify one or more of these.)
To specify multiple connection destination BB-IDs, enter a command like
"diagxbu -y -b 00 -t 01 -t 02".
XSCF>   diagxbu -y -b 00 -t 01
4.
Execute the showlogs command to confirm that the system is operating
normally.
XSCF>   showlogs error
For details, see
"3.3.5 Checking log
5.
Switch the mode switches of the master chassis and those chassis whose
XSCFs are in the standby state to Locked mode.
- For a building block configuration (without crossbar box)
Switch the mode switches of BB-ID#00 and #01 to Locked mode.
- For a building block configuration (with crossbar box)
Switch the mode switches of BB-ID#80 and #81 to Locked mode.
6.
Execute the showstatus command to confirm that there is no problem with
the crossbar units after the completion of maintenance.
XSCF>   showstatus
7.
Execute the showhardconf command to check the hardware configuration
and the status of each component.
XSCF>   showhardconf
8.
Start the entire system.
For details, see
"6.4 Starting the Entire
9.
Close the rack door.
information."
System."
Chapter 9 Maintaining the Crossbar Units
197