For details, see
system."
7.
Remove all the power cords from the PSU backplane unit or power supply
unit of the chassis requiring maintenance.
For details, see
Note - In the case of a dual power feed, make a note of the locations of the power cords
before disconnecting them to ensure that they are reinstalled correctly.
26.4
Removing an XSCF BB Control Cable
This section describes the procedure for removing the XSCF BB control cables.
Enable removal of the XSCF BB control cables before attempting to remove them. For
details, see
Caution - Before you handle any components, wear a wrist strap to ground any static
electricity. If you perform this procedure without a wrist strap, individual
components or the overall system may be damaged. For details, see
Regarding Static
1.
Remove the XSCF BB control cable from the SPARC M10-4S or the crossbar
box.
Pull out an XSCF BB control cable while pushing the lock release buttons (A in
the figure) on the both sides of the cable.
Note - The cables on the rear of the crossbar box are bundled together and fastened to the
right-hand cable support with a hook-and-loop fastener. When removing the XSCF BB
control cables, remove the hook-and-loop fastener from the cable support.
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"5.5.2 Removing the power
"26.3 Enabling the Removal of an XSCF BB Control
Electricity."
Chapter 26 Maintaining the XSCF BB Control Cables
cord."
Cable."