Fujitsu M10-4 Service Manual page 413

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Figure 25-7     Crossbar cable (optical) shapes and tabs
Number in
figure
1
Insert the crossbar cable (optical) by holding the connector part of the cable and
inserting it straight into the opening. Do not hold the cable part when inserting the
cable.
Note - Confirm that the crossbar cables (optical) are correctly connected and secure.
Note - After installing the crossbar cables (optical), use the hook-and-loop fastener to bundle
the cables together and secure them to the rear cable support.
25.6
Restoring the System
This section describes the procedure for restoring the system after installing the
crossbar cable (optical). The restoration procedure differs depending on the
maintenance type as follows:
Inactive/Cold maintenance
System-stopped maintenance
25.6.1
Inactive/Cold maintenance
1.
Connect all power cords to the SPARC M10-4S power supply unit requiring
maintenance.
For details, see
(1)
(1)
Description
Tab
"6.5.1 Installing the power
Chapter 25 Maintaining the Crossbar Cables (Optical)
cord."