9.
Install the mounting frame for the crossbar unit and then tighten the three
screws.
Note - If no crossbar unit is mounted, proceed to step 11.
10. Install all the crossbar units.
For details, see
11. Install all the PCIe card cassettes.
For details, see
Note - Reinstall the PCIe card cassettes in their original positions by referring to the notes
that you made prior to the start of maintenance.
12. Connect all the cables to the external interface.
The cables to be connected are as follows.
Note - Reconnect the cables of the external interface in their original positions by referring to
the notes that you made prior to the start of maintenance.
13. Lift the cable support to fix it.
For details, see
15.6
Restoring the System
This section describes the procedure for restoring the system after installing the
operation panel. The restoration procedure differs depending on the maintenance
type as follows:
Note - See the procedure for system-stopped maintenance for inactive/cold maintenance in a
single-chassis configuration.
Active/Cold maintenance
Inactive/Cold maintenance
System-stopped maintenance
"9.5.1 Installing a crossbar
"13.6.2 Installing a PCI Express card
Interface cable connected to the PCIe card
Crossbar cable
XSCF BB control cable
XSCF DUAL control cable
LAN cable
"6.5.2 Fixing the cable
unit."
cassette."
support."