For details, see
system."
10.3.2
Inactive/Hot maintenance
For a single-chassis configuration
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
For details, see
4.
Confirm the hardware and software configurations.
For details, see
5.
Stop the entire system.
For details, see
6.
Execute the showpparstatus command to confirm that the physical partition
requiring maintenance is powered off.
XSCF> showpparstatus -a
7.
Execute the replacefru command to release the power supply unit requiring
maintenance from the system.
XSCF> replacefru
For details, see
system."
For a building-block configuration
1.
Open the rack door.
2.
Log in to the XSCF shell.
3.
Execute the showlogs command to identify the component requiring
maintenance.
XSCF> showlogs error
For details, see
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"3.3.5 Checking log
information."
"4.2 Confirming the System
"5.4 Stopping the Entire
"5.1.1 Releasing an FRU of the SPARC M10-4/M10-4S from the
"3.3.5 Checking log
information."
Chapter 10 Maintaining the Power Supply Units
Configuration."
System."
203