Fujitsu M10-4 Service Manual page 461

Hide thumbs Also See for M10-4:
Table of Contents

Advertisement

Figure 28-24     Connector shape (cable (SIG))
2.
Secure the cable with a clamp.
3.
Support the fan shelf from below with one hand and then insert it carefully
into the chassis.
Arranging the cables in the center makes it easier to install the fan shelf.
4.
Tighten the three screws securing the fan shelf.
5.
Connect the two cables to the fan shelf.
6.
Install the lower cover and then secure it with the one screw.
7.
Install the upper cover.
8.
Slide the right and left stoppers of the upper cover outwards and then secure
the cover with the two screws.
9.
Install all the fan units.
For details, see
10. Install the front cover.
For details, see
28.5.2
Installing a cable for the connection between the
terminal board and fan backplane
Install the cable (SIG) or cable (PWR) connecting the terminal board and fan backplane.
1.
Install the cable on the terminal board.
For the cable (PWR), install the connector that has latches (A in the figure) on
both ends to the terminal board.
Install the tab (B in the figure) of the connector such that it fits in the notched
section (C in the figure) of the terminal board.
 
"19.5 Installing a Fan
"6.5.3 Installing the front
Unit."
cover."
Chapter 28 Maintaining the Cable Kit of the Crossbar Box
437