Maintenance and inspection
7. Please remove old battery pack plug from circuit board.
NOTICE
Make sure that no wires are pinched when you install the battery pack and the cover plate
again.
8. Please apply Teroson Plast sealing compound (material no. 143813) to thread part of
screws.
Exchanging the battery unit iscompleted after reinstalling the cover plate on the plug plate.
9.2.2
Motor
1
Motor power connector
2
Encoder connector
3
Before removing the encoder connector (with CAUTION label), connect the battery to the
motor as shown in the following figure.
-
9
50
Battery pack connector (including warning note)
3
b
OBT
a
BAT
Fig. 9-6: Battery unit connector diagram for S-, L- and U-axes
1
2
a
OBT*
b
BAT
5
Battery unit
4
Plug for backup
5
4