Mechanical Installation; Items Supplied - Danfoss VLT AutomationDrive FC 302 Operating Manual

90–315 kw, enclosure size d1h–d8h
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Mechanical Installation

4 Mechanical Installation

4.1 Items Supplied

Items supplied can vary according to product configu-
ration.
4
4
Make sure the items supplied and the information
on the nameplate correspond to the order confir-
mation. Illustration 4.1 and Illustration 4.2 show
sample nameplates for a D-sized drive either with
or without an extended options cabinet.
Check the packaging and the drive visually for
damage caused by inappropriate handling during
shipment. File any claim for damage with the
carrier. Retain damaged parts for clarification.
VLT
1
T/C: FC-302N250T5E20H2XGCXXXSXXXXAXBPCXXXXDX
2
P/N: 136G0205
3
250 kW / 350 HP, High Overload
4
IN: 3x380-500V 50/60Hz 463/427 A
5
OUT: 3x0-Vin 0-590Hz 480/443 A
315 kW / 450 HP, Normal Overload
IN: 3x380-500V 50/60Hz
OUT: 3x0-Vin 0-590Hz
CHASSIS/IP20
Tamb. 45 C/113 F at Full Output Current
SCCR 100 kA at UL Voltage range 380-500 V
6
1
Type code
2
Part number and serial number
3
Power rating
4
Input voltage, frequency, and current
5
Output voltage, frequency, and current
6
Discharge time
Illustration 4.1 Example Nameplate for Drive Only (D1h–D4h)
16
VLT® AutomationDrive FC 302
AutomationDrive
R
www.danfoss.com
S/N: 123456H058
567/516 A
588/535 A
ASSEMBLED IN USA
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
Danfoss A/S
6430 Nordborg
Denmark
089
CAUTION - ATTENTION:
See manual for special condition / mains fuse
`
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
Stored charge, wait 20 min.
Charge residuelle, attendez 20 min.
`
Danfoss A/S © 09/2018 All rights reserved.
VLT
AutomationDrive
R
www.danfoss.com
1
T/C: FC-302N250T5E54H2XGC3XXSXXXXALBXCXXXXDX
S/N: 123456H123
2
P/N: 134L8251
Use the following Typecode to order Drive-only replacement:
T/C: FC-302N250T5E54H2XGC7XXSXXXXALBXCXXXXDX
3
250 kW / 350 HP, High Overload
4
IN: 3x380-500V 50/60Hz 463/427 A
5
OUT: 3x0-Vin 0-590Hz 480/443 A
315 kW / 450 HP, Normal Overload
IN: 3x380-500V 50/60Hz
567/516 A
OUT: 3x0-Vin 0-590Hz
588/535 A
Type 12 / IP54
Tamb. 45 C/113 F at Full Output Current
SCCR 100 kA at UL Voltage range 380-500 V
Listed 36U0 E70524 IND. CONT. EQ.
UL Voltage range 380-500 V
CAUTION - ATTENTION:
See manual for special condition / mains fuse
Voir manuel de conditions speciales / fusibles
WARNING - AVERTISSEMENT:
6
Stored charge, wait 20 min.
Charge residuelle, attendez 20 min.
`
1
Type code
2
Part number and serial number
3
Power rating
4
Input voltage, frequency, and current
5
Output voltage, frequency, and current
6
Discharge time
Illustration 4.2 Example Nameplate for Drive with Extended
Options Cabinet (D5h–D8h)
NOTICE
LOSS OF WARRANTY
Do not remove the nameplate from the drive. Removing
the nameplate can result in loss of warranty.
ASSEMBLED IN USA
Danfoss A/S
6430 Nordborg
Denmark
`
MG34U502