Danfoss VLT AutomationDrive FC 302 Operating Manual page 102

90–315 kw, enclosure size d1h–d8h
Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Specifications
10.1.3 Electrical Data for Enclosures D1h–D8h, 3x525–690 V
®
VLT
AutomationDrive FC 302
High/normal overload
(High overload=150% current during
60 s.
Normal overload=110% current during
60 s)
Typical shaft output at 525 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 525 V) [A]
Intermittent (60 s overload)
(at 525 V) [A]
Continuous (at 575/690 V) [A]
Intermittent (60 s overload)
(at 575/690 V) [A]
Continuous kVA (at 525 V) [kVA]
Continuous kVA (at 575 V) [kVA]
Continuous kVA (at 690 V) [kVA]
Maximum input current
Continuous (at 525 V) [A]
Continuous (at 575/690 V)
Maximum number and size of cables per phase
10
10
- Mains, motor, brake, and load share
[mm
2
(AWG)]
Maximum external mains fuses [A]
Estimated power loss at 575 V [W]
Estimated power loss at 690 V [W]
3)
Efficiency
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C
(°F)]
Table 10.5 Electrical Data for Enclosures D1h/D3h/D5h/D6h, Mains Supply 3x525–690 V AC
1) For fuse ratings, see chapter 10.7 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/vltenergyefficiency. Options and
customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
3) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 10.4 Ambient Conditions. For part load losses, see www.danfoss.com/vltenergyefficiency.
100
VLT® AutomationDrive FC 302
N55K
HO
NO
HO
45
55
55
60
75
75
55
75
75
76
90
90
114
99
135
73
86
86
110
95
129
69
82
82
73
86
86
87
103
103
74
87
87
70
83
83
2x95 (2x3/0)
2x95 (2x3/0)
1)
160
1098
1162
1162
2), 3)
1057
1204
1205
2), 3)
0.98
0–590
110 (230)
110 (230)
75 (167)
75 (167)
Danfoss A/S © 09/2018 All rights reserved.
N75K
N90K
NO
HO
NO
75
75
90
100
100
125
90
90
110
D1h/D3h/D5h/D6h
113
113
137
124
170
151
108
108
131
119
162
144
103
103
125
108
108
131
129
129
157
109
109
132
104
104
126
2x95 (2x3/0)
315
315
1428
1430
1740
1477
1480
1798
0.98
0.98
0–590
0–590
110 (230)
75 (167)
± 15% (tolerance relates to variety in voltage and cable conditions). These
N110
N132
HO
NO
HO
NO
90
110
110
132
125
150
150
200
110
132
132
160
137
162
162
201
206
178
243
221
131
155
155
192
197
171
233
211
125
147
147
183
131
154
154
191
157
185
185
230
132
156
156
193
126
149
149
185
2x95 (2x3/0)
2x95 (2x3/0)
315
315
1742
2101
2080
2649
1800
2167
2159
2740
0.98
0.98
0–590
0–590
110 (230)
110 (230)
75 (167)
75 (167)
MG34U502