GE Multilin MIWII Instruction Manual page 189

Directional power protection system
Table of Contents

Advertisement

APPENDIX B
B.7.1.2 MOTOROLA FORMAT
ADDRESS
BIT
009C
00A4
00A6
0
00A7
0
00A7
1
00A8
00AA
00AC
00AE
00B0
00B2
00B3
0
00B3
3
00B3
5
00B3
7
00B3
8
00B4
0
00B4
1
00B4
3
00B4
5
00B4
7
00B5
0
00B6
00B8
00BA
00BC
00BE
00C0
00C2
00C4
00C5
3
00C6
3
00C7
00C9
00CB
00CD
00CF
00D1
00D2
3
00D3
3
00D4
00D6
00D8
00DA
00DC
00DE
00DF
3
00E0
3
00E1
00E3
GEK-113308
NAME
IDENTIFICATION
Trip Min Time
Settings Group
Relay Operation
Frequency
CT Ratio
VT Ratio
Rated Voltage
Rated MVA
Power Factor
VT Connection Type
40 Enable
32_1 Enable
32_2 Enable
32_3 Enable
Fuse Failure Enable
Enable Circle 1 Trip
Enable Circle 2 Trip
32_1 Trip
32_2 Trip
32_3 Trip
Enable Voltage Supervision
Voltage level
Circle 1 Diameter
Circle 1 Offset
Circle 1 Trip Delay
Circle 2 Diameter
Circle 2 Offset
Circle 2 Trip Delay
32_1 Power Type
32_1 Minimum/Maximum
32_1 Forward/Reverse
32_1 Alarm Level
32_1 Alarm Delay
32_1 Trip Level
32_1 Trip Delay
Block 32_1 From Online
32_2 Power Type
32_2 Minimum/Maximum
32_2 Forward/Reverse
32_2 Alarm Level
32_2 Alarm Delay
32_2 Trip Level
32_2 Trip Delay
Block 32_2 From Online
32_3 Power Type
32_3 Minimum/Maximum
32_3 Forward/Reverse
32_3 Alarm Level
32_3 Alarm Delay
MIWII Directional Power Protection System
B.7 MODBUS MAP - SETTINGS
DESCRIPTION
LENGTH
IDEN
16
Trip Min Time
4
Settings Group
2
Relay Operation
2
Frequency
2
Current CT Ratio
4
Voltage VT Ratio
4
Nominal Voltage
4
Nominal Power
4
Power Factor
4
V App
2
Enable 40
2
Enable 32 1
2
Enable 32 2
2
Enable 32 3
2
Enable Fuse
2
Trip Enable 40 1
2
Trip Enable 40 2
2
Trip Enable 32 1
2
Trip Enable 32 2
2
Trip Enable 32 3
2
Volt Superv 40
2
Voltage Level 40
4
Diam Circle 40 1
4
Offs Circle 40 1
4
Delay Circl 40 1
4
Diam Circle 40 2
4
Offs Circle 40 2
4
Delay Circl 40 2
4
Power 32 1
2
Type 32 1
2
Direction 32 1
2
Alarm Level 32 1
4
Alarm Delay 32 1
4
Trip Level 32 1
4
Trip Delay 32 1
4
Block 32 1
4
Power 32 2
2
Type 32 2
2
Direction 32 2
2
Alarm Level 32 2
4
Alarm Delay 32 2
4
Trip Level 32 2
4
Trip Delay 32 2
4
Block 32 2
4
Power 32 3
2
Type 32 3
2
Direction 32 3
2
Alarm Level 32 3
4
Alarm Delay 32 3
4
FORMAT
BYTES ARRAY
FLOAT32(INTEL)
BIT
B
BIT
BIT
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
ENUMERATION:
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
BIT
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
ENUMERATION:
BIT
BIT
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
ENUMERATION:
BIT
BIT
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
FLOAT32(INTEL)
ENUMERATION:
BIT
BIT
FLOAT32(INTEL)
FLOAT32(INTEL)
B-15

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Multilin MIWII and is the answer not in the manual?

This manual is also suitable for:

Multilin miwii1000e00hi00

Table of Contents