9.33 Eject sensor PCB

(1) Disconnect the Registration mark sensor L harness, the Registration mark sensor R
harness, and the Internal temperature sensor harness from the Eject sensor PCB.
(2) Release the Eject sensor harness from the securing fixtures. Release the Hook to remove
the Eject sensor PCB. Disconnect the Eject sensor harness from the Eject sensor PCB.
Hook
Harness routing: Refer to
Hook
Fig. 3-101
"15. Registration mark sensor ASSY, Eject sensor
Eject sensor
harness
Registration mark
sensor L harness
Registration mark
sensor R harness
Eject sensor PCB
3-113
Internal
temperature
sensor harness
Eject sensor PCB
<Back side>
PCB".