3.9

Interlock Levers

(1) Grease the contacting portions of the interlock levers on assembly.
3.10

Fan Motor

(1) Disconnect the connector from the driver PCB (Refer to 3.19).
(2) Take off the fan motor.
3.11

Registration Sensor PCB

(1) Remove the screw of the registration sensor PCB.
(2) Disconnect three connectors from the registration sensor PCB.
Registration sensor PCB
Grease
Fig. 3.11
Tape
Fig. 3.12
Registration sensor harness
Solenoid P
Solenoid C
Fig. 3.13
Grease: MolyKote EM30L
Grease
III - 8
Y-BSMXL0.14
Fan motor
Y-BSMXL0.15
Y-BSMXL0.16