ERROR INDICATIONS

This machine includes a self-diagnosis function. If the machine does not work normally it
judges that an error has occurred, and indicates the corresponding error message on the LCD,
which in turn helps the service personnel to quickly find out the problem.
3.1

Error Codes

*1
The shaded errors hardly occur under normal use. They may be caused by noise
around the installation site, variation in power supply voltage, or software failure.
The errors are reset by plugging in or unplugging the AC cord if they have occurred.
If an error occurs repeatedly, please contact Brother distributors.
Error
Codes
ASIC error or motor driver error
0101
occurred.
0102
*1
Cannot detect the synchronized signal
of the paper feed motor. The speed of
0201
the paper feed motor does not
stabilize within the specified time.
Cannot detect the synchronized signal
of the process motor. The speed of
0202
the process motor does not stabilize
within the specified time.
0203
*1
0300
*1
0305
*1
0401
*1
0402
*1
0405
*1
The center thermistor of the fuser unit
0501
has not reached the specified
temperature within the specified time.
The center thermistor of the fuser unit has
not reached the specified temperature
0502
within the specified time after it was
heated normally to the certain level.
The center thermistor of the fuser unit
0503
detected a temperature higher than
the specified value.
After the heat unit was heated
normally, the center thermistor of the
0504
fuser unit detected a temperature
lower than the specified value.
The center thermistor of the fuser unit
0505
detected a temperature rise greater than the
specified value within the specified time.
The center thermistor of the fuser unit
0506
detected a temperature fall greater than the
specified value within the specified time.
0508
*1
Description
2-17
Refer
Error
to:
Codes
The hardware detected a temperature
2-62
050A
error through the center thermistor or
the side thermistor of the fuser unit.
When the center thermistor of the fuser
unit was lower than the idle temperature,
050B
the side thermistor detected a temperature
higher than the specified temperature.
When the center thermistor of the fuser
unit was higher than the idle temperature,
2-62
050C
the side thermistor detected a temperature
lower than the specified temperature.
2-62
050D
*1
050F
*1
An error occurred in the internal
0800
temperature sensor.
Detected irregular power supply for
0900
more than 100 times.
0A01
*1
0A02 Main PCB detected the fan failure.
0A03
*1
An error occurred in the high-voltage
2-63
0B01
power supply PCB while operating.
An error occurred in the high-voltage
2-63
0B02
power supply PCB when the machine
was in the ready state.
An error occurred in the density
2-63
0C00
sensor.
2-63
0D01
*1
2-63
0D02
*1
2-63
0D03
*1
0D04
*1
Description
Confidential
Refer
to:
2-64
2-64
2-64
2-64
2-65
2-65
2-66
2-66
2-66

Advertisement