9.24 MP unit
(1) Disconnect the MP paper empty sensor harness, the MP registration sensor harness, and
the MP solenoid harness from the Main PCB, and release them from the securing fixtures.
Harness routing: Refer to
(2) Remove the two Taptite bind B M4x12 (black) screws. Release each Hook to remove the
T1 paper feed guide from the MP unit.
(3) Remove the four Taptite bind B M4x12 screws. Release each Hook to remove the MP unit.
(Only for MP models)
Main PCB
"10. Main PCB, Cartridge sensor relay
Hook
MP unit
Fig. 3-76
Hook
Hooks
T1 paper
feed guide
Taptite bind B M4x12
Fig. 3-77
3-91
MP registration
sensor harness
MP paper empty
sensor harness
MP solenoid harness
PCB".
Taptite bind B M4x12
Taptite bind B M4x12
(black)
Confidential