Error
Description
Codes
AB00
*1
When scanning the fax, white or black
AC00
correction data for the second side CIS was
not within the correct range (first time).
Image processing cannot be completed
correctly because the number of pixels
AD00
required for image processing is
insufficient in the scanned first side data.
AE00
*1
Home position is still being detected even
AF00
after the first side CIS unit was moved.
Detected that the first side CIS flat
cable or second side CIS flat cable
B000
was not inserted correctly when
function code 55 was executed.
B700
*1
B800
*1
B900
*1
A white level not within the standard
BB00
was scanned when function code 55
was executed.
When scanning the fax, white or black
correction data for the second side
BC00
CIS was not within the correct range
(second time).
A black level not within the standard
BD00
was scanned when function code 55
was executed.
The document scanning position
sensor detected that the document
BF00
length was 400 mm or longer and
could not be fed to ADF (double-side
restoration).
Timeout occurred with access request
sent to server due to incorrect server
C001
address, network disconnection, or
inactive server.
User authentication is unavailable due
to incorrect user name, incorrect
C002
password, or asynchronous date and
time between the machine and server.
Cannot access to the file because the
directory name is wrong, writing into
C003
directory is not permitted, or writing
into file is locked or not permitted.
Cannot acquire current time which is
C004
required for user authentication because
the time has not been acquired.
Failed to save data to a USB flash memory
C100
when the USB DUMP was running.
The memory is insufficient to expand
C700
the data of PC-Print.
The memory used to store secure
C800
print data exceeded the memory size
for secure print data.
Storage memory was full and data
C900
could not be saved.
CA00
*1
Refer
Error
to:
Codes
An error occurred while initializing the
D100
modem.
Detected that the modem PCB is not
2-99
D200
connected.
An error occurred while initializing the
2-99
D800
touch panel.
D900
*1
2-100
DA00
*1
A communication error occurred
2-100
DB00
between the main ASIC and the
recording ASIC.
An error occurred in the ROM check
E000
sum.
E001
*1
E002
*1
2-100
E100 Program error
An error occurred during access to the
2-101
E500
DRAM in the main PCB.
Write error in the EEPROM of the
2-101
E600
main PCB
2-101
E701 System error in the flash ROM
2-102
E702 Read error in the flash ROM
An error occurred while initializing the
2-102
E900
NFC.
Overcurrent was caused because a
USB device that did not meet the
2-102
EC00
specifications was inserted into the
USB port.
2-102
ED00
*1
2-102
EE00
*1
The spec code was not entered
2-103
F900
correctly.
2-103
FA01
*1
2-103
FA02
*1
FA03
*1
2-25
Description
Confidential