Check toner cartridge's destination
For models with touch panel
(1) Press the [5], and then [7] in the initial state of maintenance mode. "IC_ACT ALL" is
displayed on the LCD.
(2) Press the [3]. "IC_AREA ALL" is displayed on the LCD.
(3) Press the [◄] or [►] to display the toner cartridge to be authorized on the LCD.
If you want to select all colors:
If you want to select black:
If you want to select magenta:
If you want to select cyan:
If you want to select yellow:
If you want to select the toner sensor on the machine: "IC_AREA MAIN"
(4) Press the [Mono Start]. Selected toner cartridge will be authorized.
If it is authorized, "IC_AREA OK" is displayed on the LCD.
If the authorization failed, "IC_AREA NG**" is displayed on the LCD.
(** indicates an error number.) Refer to the
Memo:
When NG was displayed after performing the "IC_AREA ALL", which color cartridge
had error cannot be determined. In that case, select the color individually and perform.
(5) Press the [X]. The machine returns to the initial state of maintenance mode.
For models without touch panel
(1) Press the [▲] or [▼] in the initial state of maintenance mode to display
"MAINTENANCE 57" on the LCD, and press the [OK]. "IC_ACT ALL" is displayed on the
LCD.
(2) Press the [OK] several times. "IC_AREA ALL" is displayed on the LCD.
(3) Press the [▲] or [▼] to display the toner cartridge to be authorized on the LCD.
If you want to select all colors:
If you want to select black:
If you want to select magenta:
If you want to select cyan:
If you want to select yellow:
If you want to select the toner sensor on the machine: "IC_AREA MAIN"
(4) Press the [Start]. Selected toner cartridge will be authorized.
If it is authorized, "IC_AREA OK" is displayed on the LCD.
If the authorization failed, "IC_AREA NG**" is displayed on the LCD.
(** indicates an error number.) Refer to the
Memo:
When NG was displayed after performing the "IC_AREA ALL", which color cartridge
had error cannot be determined. In that case, select the color individually and perform.
(5) Press the [Stop]. The machine returns to the initial state of maintenance mode.
"IC_AREA ALL"
"IC_AREA BLACK"
"IC_AREA MAGENTA"
"IC_AREA CYAN"
"IC_AREA YELLOW"
<Error display>
"IC_AREA ALL"
"IC_AREA BLACK"
"IC_AREA MAGENTA"
"IC_AREA CYAN"
"IC_AREA YELLOW"
<Error display>
5-42
table on 5-39 to solve it.
table on 5-39 to solve it.