DC power supply
Rated voltage
Permitted voltage range
Mains and voltage buffering time
Rated current
Rated current, load-dependent
Power consumption
Inrush current I
Maximum permitted transients
Minimum time between two transients
Internal protection
1
7.10

Interface description

7.10.1
24 V DC
Power supply 24 V DC 2-pin
Pin
1
2
7.10.2

DVI-D

DVI-D, 25-pin socket
Pin
1
2
3
4
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE
1
t
2
The power loss generally corresponds to the specified value for power consumption.
Meaning
+24 V DC
Ground
Name
TMDS data2-
TMDS data2+
TMDS Data2 shield
NC
Meaning
DVI data output 2-
DVI data output 2+
Cable shield DVI data output 2
Not assigned
Technical information
7.10 Interface description
24 V DC
+19.2 V ... +28.8 V
20 ms
0.2 A
0.17 ... 0.25 A
4.8 W
0.5 A
s
2
35 V (500 ms)
50 s
Electronic