Interface Configuration - Siemens SIMOVERT MASTERDRIVES 6SE7087-6CX86-2BA1 Manual

Active front end (afe) afe rectifier / regenerative feedback unit ac-dc modular design for construction types e to j
Table of Contents

Advertisement

01.2004
12.10

Interface configuration

PNU
Parameter Name in OP1
*:conf-P
Description
P680
SCom1 Act Value
*
Output of actual values via serial interface SST1
2A8Hex
Defines which parameter must be transferred at which telegram
position.
Notes:
• Status word 1 (r968) should be assigned to
word 1.
• In the case of double word parameters (type I4),
the associated parameter number must be
entered in two consecutive words or else only the
most significant word will be transferred.
• The length (number of words) of the process data
section in the telegram is set via P685, index i001.
Indices: i001 = W01: Word 01 of (process data section)
i002 = W02: Word 02 of (process data section)
...
i016 = W16: Word 16 of (process data section)
Type=O2;
PKW: 1HEX=1.0
P682
SCB Protocol
The SCB board can be operated as a
2AAHex
master for the SCI boards or as a
communications board (see SCB Operator's Guide).
Parameter values: 0 = Master for SCI boards
Precondition:
The associated SCB board must be logged on
via P090 or P091
Type=O2;
PKW: 1HEX=1.0
P683
SCom/SCB BusAddr
*
Bus address of serial interfaces (see Section "Serial interfaces")
2ABHex
Indices: i001 = SST1: Bus address of serial interface 1 (CUSA)
i002 = SCB: Bus address of SCB if P682 = 1, 2
Type=O2;
PKW: 1HEX=1.0
P684
SCom/SCB Baud
*
Baud rate of serial interfaces
2ACHex
Parameter values: 1:
Indices: i001 = SST1: Baud rate of ser. interface 1 (CUSA)
i002 = SCB:
Type=O2;
PKW: 1HEX=1.0
Siemens AG
6SE7087-6CX86-2BA1
SIMOVERT MASTERDRIVES AFE
of the telegram
of the telegram
of the telegram
PZD Gr.: 0
1 = 4-wire USS
2 = 2-wire USS
3 = Peer to Peer
4 = Not assigned
5 = Not assigned
PZD Gr.: -
PZD Gr.: -
300 baud
8:
2:
600 baud
9:
3:
1200 baud
10:
4:
2400 baud
11:
5:
4800 baud
12: 115200 baud
6:
9600 baud
13: 187500 baud
7: 19200 baud
Baud rate of SCB if P682 = 1, 2, 3
PZD Gr.: -
Operating Instructions
Range
[Unit]
Value Texts
0 to 999
0 to 5
SCI module
4-wire USS
2-wire USS
Peer-2-Peer
Option 1
Option 2
0 to 31
1 to 13
38400 baud
57600 baud
76800 baud
93750 baud
Parameter List
# of Indices
read:
_/_
Factory
write:
_/_
Settings
16
3 / BR
i001=968
3 / BR
i002=0
i003=0
i004=0
i005=0
i006=0
i007=0
i008=0
i009=0
i010=0
i011=0
i012=0
i013=0
i014=0
i015=0
i016=0
3 / H BR
0
3 / H
2
3 / BR
i001=0
3 / BR
i002=0
2
3 / BR
i001=6
3 / BR
i002=6
12-27