ACS510 User's Manual
Relay Output Control
Using the fieldbus for relay output control requires:
• Drive parameter values set as defined below.
• Fieldbus controller supplied, binary coded, relay command(s) in the appropriate
location. (The location is defined by the Protocol Reference, which is protocol
dependent.)
Drive Parameter
1401
1402
1403
1410
(Note 1)
1411
(Note 1)
1412
(Note 1)
1. More than 3 relays requires the addition of a relay extension module.
Note! Relay status feedback occurs without configuration as defined below.
0122
0123
Analog Output Control
Using the fieldbus for analog output control (e.g. PID setpoint) requires:
• Drive parameter values set as defined below.
• Fieldbus controller supplied analog value(s) in the appropriate location. (The
location is defined by the Protocol Reference, which is protocol dependent.)
Drive Parameter
1501
0135
1507
0136
Supplied from China by: Guangzhou Tofee Electro Mechanical Equipment Co., Ltd
Email: info@tofee.com.cn
Value
1
35 (
RELAY OUTPUT
COMM
2
35 (
RELAY OUTPUT
COMM
3
35 (
RELAY OUTPUT
COMM
4
35 (
RELAY OUTPUT
COMM
5
35 (
RELAY OUTPUT
COMM
6
35 (
RELAY OUTPUT
COMM
Drive Parameter
1-3
RO
STATUS
4-6
RO
STATUS
Value
1
135 (
AO
CONTENT SEL
COMM VALUE
1
COMM VALUE
2
136 (
AO
CONTENT SEL
COMM VALUE
2
COMM VALUE
Description
)
Relay Output 1 controlled
by fieldbus.
)
Relay Output 2 controlled
by fieldbus.
)
Relay Output 3 controlled
by fieldbus.
)
Relay Output 4 controlled
by fieldbus.
)
Relay Output 5 controlled
by fieldbus.
)
Relay Output 6 controlled
by fieldbus.
Description
Relay 1...3 status.
Relay 4...6 status.
Description
1) Analog Output 1
controlled by writing to
parameter 0135.
2) Analog Output 2
controlled by writing to
parameter 0136.
149
Modbus Protocol Reference
ABB DRV
DCU PROFILE
40134 bit 0 or 00033
40134 bit 1 or 00034
40134 bit 2 or 00035
40134 bit 3 or 00036
40134 bit 4 or 00037
40134 bit 5 or 00038
Modbus Protocol
Reference
ABB DRV
DCU PROFILE
40122
40123
Modbus Protocol
Reference
ABB DRV
DCU PROFILE
40135
40136
Embedded Fieldbus