• The table below shows the ACS510 PFC motor assignments for some typical settings in the Relay Output
parameters (1401...1403 and 1410...1412), where the settings are either =31 (
where the Autochange function is disabled (8118
Parameter Setting
1
1
1
1
1
4
4
4
4
4
0
0
0
1
1
1
2
3
0
1
31 X X X X X 1 Aux.
31 31 X X X X 2 Aux.
31 31 31 X X X 3 Aux.
X 31 31 X X X 2 X
31 31 31 31 31 31 6 Aux.
31 31 X X X X 1* Aux.
* = One additional relay output for the PFC that is in use. One motor is in "sleep"
when the other is rotating.
• The table below shows the ACS510 PFC motor assignments for some typical settings in the Relay Output
parameters (1401...1403 and 1410...1412), where the settings are either =31 (
where the Autochange function is enabled (8118
Parameter Setting
1
1
1
1
1
4
4
4
4
4
0
0
0
1
1
1
2
3
0
1
31 31 X X X X
31 31 31 X X X
X 31 31 X X X
31 31 31 31 31 31 5 PFC
31 31 X X X X 0** PFC
** = No auxiliary motors, but the autochange function is in use. Working as a
standard PID-control.
8118 AUTOCHNG INTERV
Controls operation of the Autochange function and sets the
interval between changes.
• The Autochange time interval only applies to the time when
the speed regulated motor is running.
• See parameter 8119
Autochange function.
• The drive always coasts to a stop when autochange is
performed.
• Autochange enabled requires parameter 8120
value > 0.
0.0 =
– Disables the Autochange function.
NOT SEL
0.1...336 – The operating time interval (the time when the start
signal is on) between automatic motor changes.
-0.1 =
– Forces the interval to value 36...48 s.
TEST MODE
Warning! When enabled, the Autochange function requires
the interlocks (8120 interlocks = value > 0) enabled. During
autochange the interlocks interrupt the drive's power output,
preventing damage to the contacts.
Start-Up
Supplied from China by: Guangzhou Tofee Electro Mechanical Equipment Co., Ltd
Email: info@tofee.com.cn
ACS510 Relay Assignment
1
8
Autochange Disabled
4
1
RO1
RO2
RO3
1
1
2
7
X
X
Aux.
X
Aux.
Aux.
Aux.
Aux.
Aux.
Aux.
Aux.
X
ACS510 Relay Assignment
1
8
Autochange Enabled
4
1
RO1
RO2
RO3
1
1
2
7
1 PFC
PFC
X
2 PFC
PFC
PFC
1 X
PFC
PFC
PFC
PFC
PFC
X
for an overview of the
AUTOCHNG LEVEL
INTERLOCKS
= 0).
AUTOCHNG INTERV
RO4
RO5
RO6
X
X
X
X
X
X
X
X
X
X
X
X
Aux.
Aux.
Aux.
X
X
X
= value > 0).
AUTOCHNG INTERV
RO4
RO5
RO6
X
X
X
X
X
X
X
X
X
PFC
PFC
PFC
X
X
X
Relay Logic
ACS510
=
ACS510 User's Manual
), or =X (anything but 31), and
PFC
), or =X (anything but 31), and
PFC
PFC with Autochange mode