Operation
Sharpness (DDE Gain)—Enhances image details and/or suppresses fixed pattern noise. Range 0 to
·
100.
AGC Filter—Determines how quickly a scene adjusts when a hot object appears (or disappears) within
·
the AGC ROI. If set to a low value, when a hot object enters the ROI, the AGC will adjust more slowly
to the hot object, resulting in a more gradual transition. Range 0 to 100.
Advanced Settings
Tail Rejection—Defines the percentage of the total number of pixels in
·
the array the camera excludes prior to maximizing the dynamic range
available for the content of the scene. Specify the specified percentage of
pixels the cameras removes from both the highest and lowest end of the
scene's dynamic range prior to AGC. This excludes outliers and the most
extreme portions of the scene that might be of less interest. To avoid
excluding important scene content, FLIR recommends specifying tail
rejection less than 1%. Range 0 to 100.
Plateau Value—Defines how many shades of gray the camera devotes
·
to large areas of similar temperature in the scene. Increasing the plateau
value increases the shades of gray the camera devotes to those large
areas, and vice versa. Range 0 to 100.
Linear Percent—Defines the percentage of linearity the camera
·
incorporates into the data mapping. Increasing the linear percent value
more accurately retains the visual representation of an object's temperature. Range 0 to 100.
Detail Headroom—Defines the amount of 8-bit dynamic range the histogram-equalized data uses.
·
Increasing the detail headroom value increases the shades of gray the camera devotes to the top and
bottom of the dynamic range. Range 0 to 100.
Smoothing Factor—Defines how much of the scene DDE enhances or suppresses. Range 0 to 100.
·
3.6

Input/Output (I/O) Page

Adjust local and external I/O settings on the I/O page.
For local I/O connections:
·
For information about the local I/O connector, see
I/O Devices
1.800.561.8187
Input settings
Page.
427-0108-00-10 - Revision 100 - December 2020
This document does not contain any export-controlled information.
www.
Output settings
information@itm.com
.com
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elara 427-0108-00-00

Table of Contents