Installation
If using PoE, make sure the PoE switch or injector:
·
o Is a Power Sourcing Equipment (PSE) device
o Supports IEEE 802.3at (PoE+)
If using an external AC or DC power supply, connect the power supply's wires to the appropriate
·
connectors on the
Warnings
Make sure the camera's power cable is properly connected. All electrical work must be performed in
·
accordance with local regulatory requirements.
Use a UL Listed Power Adapter that meets LPS (Limited Power Source) requirements.
·
Note that the camera's maximum power consumption is 17 W.
·
2.5

Initial Configuration

FLIR recommends configuring the camera on a bench or in a lab before mounting and aiming it.
However, it is also possible to mount the camera before configuring it, which could be more appropriate
for certain installations.
You can configure the camera using the FLIR Discovery Network Assistant (DNA) software tool —
version 2.3.0.19 or higher — the camera's web page, or a supported VMS.
Task
Discover camera IP address
Configure IP address, mask, and gateway
Configure DNS settings, MTU, and Ethernet speed
Change user credentials
Configure more than one camera at the same time
Notes
FLIR recommends using the DNA tool to discover the camera on the network. It does not require a
·
license to use and version 2.3.0.19 or higher is a free download from
one camera at the same time, see the DNA User Guide. While the software is open, click the Help
icon
.
For more information about using a supported VMS to configure one or more cameras at the same
·
time, see the VMS documentation.
To configure the camera on a bench or in a lab before mounting and aiming it, do the following:

Connect the Camera

·
Discover the Camera and Configure for Networking
·
2.5.1
1. Attach an Ethernet cable from the network switch to the RJ45 connector for a 10/100 Mbps Ethernet
and IEEE 802.3at PoE+ connection. Ethernet is required for streaming video and for configuring the
camera.
1.800.561.8187
system
cable.
. For more information about using the DNA tool, including how to configure more than
Connect the Camera
427-0108-00-10 - Revision 100 - December 2020