Camera Overview

1
Camera Overview
The FLIR Elara FR-345-EST is an affordable, fixed-mount radiometric camera for accurately measuring
skin temperature* at medium- to high-throughput entry control points. Equipped with on-edge, intelligent
face detection, Elara FR-345-EST issues on-screen prompts to individuals when they need to remove
eyeglasses, while also guiding them to the correct position for best measurement. The non-contact
camera automatically locates and measures the inner canthus (corner of the eye) within one second and
provides an instant pass/fail graphic to the individual. Integration with VMS systems further streamlines
workflow and decision-making for facilities, while helping security personnel maintain a safe distance from
potential health risks.
The Elara FR-345-EST camera includes a thermal sensor; a Full HD 1080p visible light camera; and
digital I/O. When the camera is connected to an IP network, it functions as a server, providing services
such as camera control, video streaming, and network communications. The server uses an open,
standards-based communication protocol to communicate with FLIR and third-party video management
system (VMS) clients, including systems that are compatible with ONVIF®. These clients can be used to
control the camera and stream video during day-to-day operations. For a list of supported VMS clients,
an IP network using H.264 and MJPEG encoding.
For safety, and to achieve the highest levels of performance from the camera system, always follow the
warnings and cautions in this manual when handling and operating the camera.
* DISCLAIMER: Contagions such as COVID-19, SARS, and other diseases can produce symptoms like
elevated skin temperature—a possible sign of infection. While this FLIR camera is not capable of
detecting or diagnosing viruses, it represent a simple, preliminary measure for mitigating further
contagion and possible rebound, providing the confidence to return to normalcy. FLIR devices are
intended for use as an adjunct to clinical procedures in the screening of skin surface temperature.
Various environmental and methodological factors can impact thermal imaging; therefore, it should not be
relied upon as the sole determinant of a person's body temperature. Use of a medical device will be
needed to identify elevated body temperature.
Related Documentation
Elara FR-345-EST Quick Install Guide
·
FLIR Security Cameras - Accessory Guide
·
CB-WLBX-G4 Wall & Surface Mount Kit Installation Guide
·
FLIR CGI Interface Description 2.1
·
Nexus CGI WebSockets Manual
·
FLIR Sensors SDK Programmer's Guide
·
1.1

Accessing Product Information from the FLIR Website

Up-to-date resources for the camera, including the FLIR Discovery Network Assistant (DNA) software
tool — version 2.3.0.19 or higher — and this installation and user guide, are available from the camera's
1.800.561.8187
. The video from the camera is viewed by streaming it over
427-0108-00-10 - Revision 100 - December 2020
This document does not contain any export-controlled information.
www.
.com
information@itm.com
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elara 427-0108-00-00

Table of Contents