7.5.3 TCP Server

In basic parameter interface, set output information as Input Variable, and enter Local IP and
Local Port according to actual solution demands.
Note
Input Variable currently supports format result data or result of other communication tools.
In display interface, enable Display Text to set text's color, front size, transparency, position X, and
position Y.

7.5.4 Serial

In basic parameter interface, set output information as Input Variable, and enter Serial Port
Mode, Baud Rate, Parity Bit and Stop Bit according to actual solution demands.
Note
● Data Bit is 8 by default, and it can be read only.
● Input Variable currently supports format result data or result of other communication tools.
In display interface, enable Display Text to set text's color, front size, transparency, position X, and
position Y.