Battery Discharge Indicator; Standard Machine; Machine With Battery Cut Out Option + Hourmeter - JLG TOUCAN DUO Service Manual

Table of Contents

Advertisement

III-17

3.17 Battery discharge indicator

!
CAUTION
Failure to correctly maintain battery charge
or a battery discharge exceeding 80% of its
capacity will damage the battery and the
electrical motors.

3.17.1 Standard machine

The indicator is made of 3 indicator lights located on
the top left hand side of the emergency control box. It
indicates the state of charge of the battery (refer to
picture below).
Green indicator light :
The battery is between full charge and 70%
discharge.
Orange indicator light :
The battery is between 70% and 80%
discharged. It must be recharged before
resuming operation.
Red indicator light :
Battery discharge exceeds 80% of its capacity.
The battery must imperatively be charged.
Continuing to use the machine will damage the
battery.
NOTE
A red indicator light is located on the platform
control panel and has the same functions as
the one located on the battery discharge
indicator.
Models
Updated 06-2015
GENERAL
TOUCAN Duo
3.17.2 Machine with battery cut out option
+ hourmeter
F
: Hourmeter
1
F
: Discharge indicator
2
As the battery discharges, the bar lit
in 1 moves from the right to the left (5
green bars followed by 3 orange bars).
0
At this point, the penultimate led flashes indicating
"energy reserve" (70% discharged).
The 2 leds most to the left flash indicating "empty"
(80% discharged). At this point, power is cut-off. The
battery must be recharged.
NOTE
When the battery is 80% discharged, the mast
elevation movement is impossible. Return the
machine to its lowered position and drive the
machine to the charging station to charge
the battery.
III-17