Lithium ION Charge Indicator
The indicator shows the present charge condition of the
Lithium ION battery pack as specified in table below.
Battery Pack
38V and 48V Systems
1st phase - recharging with max current available
2nd phase - recharging with reduced current
3rd phase - Cells under light charge
4th phase - Equalization/standby
72V and 83V Systems
1st phase - recharging with max current available
2rd phase - Cells under light charge
3th phase - Equalization/standby
76V Systems
1st phase - recharging with max current available
2rd phase - Equalization/standby
3rd phase - End of charge
38V, 48V and 72V Systems Fault
The battery pack is disconnected (contactor open)
83V Systems Fault
The battery pack is disconnected (contactor open)
31215460
Table 2-5. Lithium ION Battery Charge Indicator
1st Generation
Yellow
Yellow Flash
2nd Generation
Red Steady
Red Flashing
Yellow Flash
Yellow
Red Steady
Orange Flash
Green Steady
-
Green/Red Flash
-
Green
SECTION 2 - SERVICE PROCEDURE
3rd Generation
Yellow Flash
Yellow
-
-
-
Red Steady
Green Flash
Green Steady
-