Installing The Front Mounting Front Perc Module - Dell EMC PowerEdge R650 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge R650:
Table of Contents

Advertisement

Steps
1. Using a Phillips #2 screwdriver, loosen the captive screws on the front PERC module.
2. Pull the front PERC module to disengage from the connector on the drive backplane.
3. Tilt and lift the front PERC module out of the system.
NOTE:
The numbers on the image do not depict the exact steps. The numbers are for representation of sequence.
Figure 39. Removing the front mounting front PERC module
Next steps
1.
Replace the front mounting front PERC

Installing the front mounting front PERC module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in
3.
Remove the drive backplane
4. If installed,
remove the air
5. Route the cable properly to prevent the cable from being pinched or crimped.
Steps
1. Connect the PERC cable to the front PERC module.
2. Align the front PERC module at an angle until the tray touches the slot in the system.
50
Installing and removing system components
module.
Safety
instructions.
Before working inside your
cover.
shroud.
system.