6 Troubleshooting
6.2.1 Connection setup
Continued
Connecting to the Service Box
Continues on next page
100
2 Add the IP address 192.168.125.* in the Exceptions field.
xx1300002202
Note
An alternate way to configure the computer correctly is to leave the connection
defined as DHCP and plug the computer to the external service port if the service
box is connected to the external service port and also to the service port on the
computer unit. In this case, the service port will give an IP address to the
computer, that is, 192.168.125.xxx and should work to dialogue with the service
box on 192.168.125.83.
For IRC5 systems, DHCP configuration works automatically, however, for S4Cplus
systems it must be activated manually.
1 Open Internet Explorer.
2 Browse the Service Box with IP address http://192.168.125.83.
© Copyright 2019 ABB. All rights reserved.
Product manual - Connected Services
3HAC060439-001 Revision: E