3 Installation of Service Box in Robot Controllers
3.7 Verifying the installation of the service box
Continued
LED
KEY
PWR
USR
ST
@
DI2
T2M
LINK/ACT
WAN/LED
If the LEDs do not follow the preceding scheme, see
Connection and test
1
2
3
Continues on next page
54
Indication
Digital Input used for remote Access Key
Green when power is connected.
Off or flashing during the initialization phase.
Green when the initialization finished successfully.
Green after approximately 5 minutes if WAN internet transmission is possible
(3G/ WiFi).
Green when connection to the ABB server is successful.
Digital Input 2 (Not used)
Should be green when Talk2M connection is used (Wired, WiFi or 3G with
customer SIMs)
Flashing green when the information is sent through the corresponding Ether-
net connection.
Green for LAN ports (1,2,3), Red for port WAN (4)
Note
In some countries, it could take up to 15 minutes to initiate the 3G communication
(ST, USER and @ LEDs green) at the first installation or after a reset of the
Service Box.
Action
Transfer the following to the Technical Ser-
vice Engineer / Field Service Engineer:
SIM card number
serial number of the Service Box
serial number of the robot controller
The Technical Service Engineer / Field Ser-
vice Engineer will make a connection
between the Service Box and the controller
in the Connected Services application.
Test the connection by creating a test alarm.
© Copyright 2019 ABB. All rights reserved.
LEDs on page
Note
The Service Box is marked with a unique
serial number on a label. This information
together with the serial number of the ro-
bot controller and the SIM card number
is valuable information to get traceability
about which Service Box is connected to
which robot controller.
First example of test alarm:
Disconnect the communication cable for
an I/O device that is successfully commu-
nicating with the robot. The resulting error
is: 71058 Lost communication with I/O
unit.
Second example of test alarm:
Press the emergency stop button. The
resulting error is: 10013 Emergency stop
state.