Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of
a person.The meanings of the symbols are as follows.
Disregard of the warning symbol can cause improper operation which may cause death
WARNING
or serious injury.
Disregard of the caution symbol can cause improper operation which may cause injury of a
CAUTION
person or damage the object.
NOTE
Special attention is required to the section of this symbol.
NOTE
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
NOTE
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door
-Wet floor
-Vibrating header or mounting surface
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity
-Highly reflecting floor or highly reflecting objects around the door
SPECIFICATIONS
Model
: i-oneX T
Cover color
: Black
Mounting height
: 6'7" to 9'10" (2.0m to 3.0m)
Detection area
: See DETECTION AREA
Detection method
: Active infrared reflection
Depth angle
: Approach area -15° to +10°
adjustment
Presence/Motion area -10° to +8°
Power supply
: 12 to 24VAC ±10% (50 / 60 Hz)
12 to 30VDC ±10%
Power consumption
: < 2.5W (< 4VA at AC)
: See Operation indicator table
Operation indicator
Activation output
: Form A relay
50V 0.3A Max.(Resistance load)
Test input
: Opto coupler
Voltage 5 to 30VDC
Current 6mA Max.(30VDC)
Operation indicator table
Status
Operation indicator color
Stand-by (installation mode)
Stand-by (operation mode)
*1)
BLUEZONE (1st row) detection(
2nd row detection
3rd/4th row detection
5th row detection
Orange blinking
Approach (6th row) detection
Signal saturation
Slow Green blinking
Sensor failure
Fast Green blinking
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : See BLUEZONE AREA
OUTER DIMENSIONS AND PART NAMES
1' 5/16" (312)
9 13/16" (250)
4 13/16" (123)
4 15/16" (125)
1 7/16" (36)
(2)
(3)
(1)
(12)
(11)
(6)
(10)
(4)
(5)
BLUEZONE AREA
When dipswitch 5 is set to "ON", the BLUEZONE area, that provides extra safety over the threshold, is activated.
In case the BLUEZONE function is not required, set dipswitch 5 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 5.
4th row
3rd row
5th row
2nd row
Approach
BLUEZONE
(6th row)
(1st row)
Safety output
: Form A relay
50V 0.3A Max.(Resistance load)
Output hold time
: 0.5 to 1.5sec.
Response time
: < 0.3sec.
Operating temperature : -31°F to 131°F(-35°C to +55°C)
Operating humidity
: < 80%
IP rate
: IP54
Weight
: 14.6oz (420g)
Accessories
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 9'10" (3m)
1sec.
Yellow
Green
Blue
Red blinking
Red
Orange
[inch (mm)]
2 1/16" (52.5)
(3)
(2)
(1) Connector
(11)
(2) Mounting holes (for retrofit)
(3) Mounting holes
(4) Operation indicator
(5) Width adjustment screws
(6) Depth angle adjustment screw (Presence/Motion)
(7) Depth angle adjustment screw (Approach)
(8) Sensitivity potentiometers
(8)
(7)
(9) Dipswitches
(9)
(10) Detection window
(11) Cover fixing
(12) Area adjustment tool
4th row
3rd row
5th row
2nd row
Approach
BLUEZONE
(6th row)
(1st row)
2nd row overlapping
the threshold
DETECTION AREA
The chart shows the values at depth angle 0°
A
7'3" (2.20)
8'2" (2.50)
B
9" (0.22)
10" (0.25)
C
6" (0.16)
D
2" (0.06)
E
7" (0.17)
F
1'7" (0.49)
1'10" (0.55)
G
1'8" (0.50)
1'11" (0.58)
H
2'8" (0.82)
3'1" (0.93)
I
2'10" (0.86)
3'3" (0.99)
J
3'5" (1.04)
3'10" (1.18)
K
3'7" (1.09)
4'1" (1.24)
L
4'9" (1.45)
5'5" (1.65)
M
8'1" (2.46)
9'2" (2.79)
N
4'6" (1.38)
5'2" (1.57)
O
7'1" (2.15)
8'
P
8'4" (2.53)
9'5" (2.88)
Q
10'6" (3.20)
12'
R
12'1" (3.68)
13'9" (4.18)
S
14'
(4.27)
15'11" (4.86)
T
13'5" (4.10)
15'4" (4.67)
U
16'9" (5.10)
19'
Approach area
*Mounting Height = 7'3"(2.2m)
-15°
L
2'2" (0.67)
4'9" (1.45)
M
5'1" (1.54)
8'1" (2.46)
O
5'7" (1.69)
7'1" (2.15)
Q
8'3" (2.52)
10'6" (3.20)
S
12'
(3.66)
14'
The actual detection area may become smaller depending on the ambient light, the color / material of
NOTE
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
2"(50mm) / sec. or faster than 4'11"(1500mm) / sec.
INSTALLATION
1
1. Affix the mounting template at the desired mounting position.
Refer to the chart in below.
2. Drill two mounting holes of ø1/8" (ø3.4mm).
3. To pass the cable through the header, drill a wiring hole of ø5/16" (ø8mm).
4. Remove the mounting template.
5. Remove the housing cover with screw driver as shown below.
Fix the sensor to the mounting surface with the two mounting screws.
Screw driver
Header
Sensor
Maximum distance (Y)
Y
1sec.
X
X
H
Door
Floor
NOTE
CAUTION
Risk of getting caught
2
Wire the cable to the door controller as shown below.
Power
1
supply
Activation
2
output
Safety
3
output
Test
4
input
WARNING
Danger of electric shock
3
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See ADJUSTMENTS 5. Dipswitch settings, Table 1)
Make sure to connect the cable correctly to the door controller before turning the power ON.
NOTE
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
Do not touch the dipswitches before turning the power ON, otherwise an error occurs.
4
Place the housing cover.
If wiring is to be exposed, break the knockout.
WARNING
Danger of electric shock
[feet,inch(m)]
9'10" (3.00)
1'
(0.31)
7" (0.18)
8" (0.21)
A
3" (0.07)
3" (0.08)
8" (0.20)
9" (0.24)
BLUEZONE
(1st row)
2'2" (0.65)
2nd row
2'4" (0.70)
3rd row
3'8" (1.11)
4th row
5th row
3'11"(1.19)
Approach
4'8" (1.41)
(6th row)
4'11" (1.49)
6'6" (1.98)
11'
(3.35)
6'2" (1.89)
(2.45)
9'8" (2.95)
11'4" (3.45)
(3.65)
14'4" (4.38)
16'6" (5.02)
Presence area
19'2" (5.84)
Motion area
Approach area
18'4" (5.60)
(5.79)
22'10" (6.95)
[feet,inch(m)]
+10°
6'9" (2.06)
12'
(3.65)
8'2" (2.50)
11'8" (3.56)
(4.27)
15'7" (4.76)
Insert
1
Screw driver
Cover fixing
2
Slide
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
H
6'7" (2.00)
7'7" (2.30)
8'2" (2.50)
No limit
0
2" (0.05)
4" (0.10)
4" (0.10)
4" (0.11)
4" (0.10)
3" (0.08)
4" (0.09)
4" (0.10)
6" (0.15)
2" (0.06)
3" (0.08)
3" (0.08)
8" (0.20)
2" (0.05)
3" (0.07)
3" (0.08)
10" (0.25)
2" (0.05)
2" (0.06)
3" (0.07)
-
-
12" (0.30)
-
Make sure not to mount the bottom of the sensor lower than the bottom of the header.
Make sure to affix the mounting template as described in the above chart,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
1.Grey
12 to 24VAC±10% / 12 to 30VDC±10%
1
2.Grey
3.White
Form A relay 50V 0.3A Max.
2
4.Yellow
5.White stripe
3
Form A relay 50V 0.3A Max.
6.Yellow stripe
7.Red (+)
Opto coupler / Voltage: 5 to 30VDC
4
8.Black (-)
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain cover
(Separately available) otherwise electric shock or breakdown of
the sensor may occur.
Mounting
C
surface
B
D
E
F
G
H
I
J
K L
M
N
O
P
Q
R
S
T
U
:1st-4th row
:5th row
:6th row
-15°
10°
Lock release is in the identical position
on both side of the sensor.
[feet,inch(m)]
9'2" (2.80)
9'10" (3.00)
5" (0.12)
5" (0.12)
4" (0.11)
4" (0.11)
4" (0.09)
4" (0.10)
4" (0.09)
4" (0.09)
3" (0.08)
3" (0.08)
-
-
Knockout
Knockout

Advertisement

loading

Summary of Contents for Optex i-oneX T

  • Page 1 5. Remove the housing cover with screw driver as shown below. SPECIFICATIONS Fix the sensor to the mounting surface with the two mounting screws. Insert Model : i-oneX T Safety output : Form A relay Cover color : Black 50V 0.3A Max.(Resistance load)
  • Page 2 When Dipswitch 14 is set to "ON", both Manufacturer North and South America Subsidiary the activation & safety relay outputs will OPTEX Co.,LTD. OPTEX INCORPORATED East coast office operate simultaneously regardless of Simultaneous 5-8-12 Ogoto Otsu 520-0101, Japan 18730 S.