RS232 Modifiers

RS232 Baud Rate

Baud Rate sends the data from the scanner to the terminal at the specified rate.
The host terminal must be set for the same baud rate as the scanner.
115,200.

RS232 Word Length: Data Bits, Stop Bits, and Parity

Data Bits sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text, digits,
and punctuation), select 7 data bits. For applications that require use of the full
ASCII set, select 8 data bits per character.
HH490 User Guide
300
1200
4800
19200
57,600
Default = 8.
Default =
600
2400
9600
38400
* 115,200