Example 3:
CAN messages with the CAN identifiers 0x123, 0x124, 0x125 0x621, and 0x726 are
transmitted. The required filter mask must be determined using an XNOR gate. Other CAN
messages that comply with the filter mask are also received. CAN messages with other CAN
identifiers are not received, but forwarded to the next online CAN object.
Set the filter mask:
Online CAN object
11-bit CAN identifier (hex): 0x123
11-bit CAN identifier (hex): 0x124
11-bit CAN identifier (hex): 0x125
11-bit CAN identifier (hex): 0x621
11-bit CAN identifier (hex): 0x726
XNOR gate for filter mask
Filter mask 0xF8 (hex)
Example 3: filter mask for CAN messages
PROEMION GmbH | Phone: +49 661 9490-600 | Fax: +49 661 9490-666 | info@proemion.com | proemion.com | Version 1.0
Device Manual
Binary
001 0010 0011
001 0010 0100
001 0010 0101
110 0010 0001
111 0010 0110
000 1111 1000
xxx 1111 1xxx