PROEMION CANlink wireless 3000 Series Device Manual page 108

Hide thumbs Also See for CANlink wireless 3000 Series:
Table of Contents

Advertisement

In the P
ERFORMANCE
Parameter
CAN
RECEIVE LOOPS
PER CYCLE
W
IRELESS RECEIVE
LOOPS PER CYCLE
Performance Parameters field
In the P
M
OWER
sleep function is enabled, the CANlink wireless goes into sleep mode after clamp 15 is switched
off. The CANlink wireless is put into operating mode via clamp 15 or a CAN message.
Parameter
E
NABLE ACTIVE SLEEP
15
AND CLAMP
WAKEUP
T
IME UNTIL SLEEP AFTER
15
CLAMP
REMOVAL
Power Management Settings field
In the SDO S
ERVER
Parameter
S
ERVER TIMEOUT
RX COB-ID (
SERVER
TX COB-ID (
SERVER
RX COB-ID (
SERVER
TX COB-ID (
SERVER
/
HEXADECIMAL
L
OAD DEFAULTS
SDO Server Settings
NOTICE
When the COB IDs are set to the default values, the device's node ID is automatically added
according to the CANopen specification. If other values are defined, they are directly used
without adding the device's node ID.
PROEMION GmbH | Phone: +49 661 9490-600 | Fax: +49 661 9490-666 | info@proemion.com | proemion.com | Version 1.0
Device Manual
P
field, prioritize data transmission in certain directions.
ARAMETERS
Description
Input field for prioritizing CAN reception.
Input field for prioritizing WLAN / Bluetooth reception.
S
field, define the parameters for the sleep function. When
ANAGEMENT
ETTINGS
Description
Enable/disable sleep function.
Input field for the time after which the CANlink wireless goes into
sleep mode due to a status change of clamp 15 to low. Enter the
time in seconds.
S
field, define the parameters for the SDO server.
ETTINGS
Description
Input field for time.
1)
Input field for the COB-ID. Default value: 0x600
1)
Input field for the COB-ID. Default value: 0x580
2)
Input field for the COB-ID. Default value: 0x600
2)
Input field for the COB-ID. Default value: 0x580
Toggle between hexadecimal and decimal display.
DECIMAL
Load default SDO server settings.