lìíéìí=m~íÅÜáåÖ
With your router(s) specified, you can now set up output patching. This procedure enables
you to define which router outputs are connected to which ScreenPRO-II inputs.
Use the following procedure to set up each router's output patching.
1.
2.
3.
4.
B
A
C
K
Figure D-9. Output Patch Menu (sample)
5.
6.
7.
8.
ScreenPRO-II • User's Guide
Note
This procedure is not required if you are using " Internal "
source routing on your ScreenPRO-II units.
From the previous "
System Connection
down which physical router outputs are used, and which physical ScreenPRO-II
inputs are used.
On the Encore or ScreenPRO-II Controller console, press SYSTEM > { ROUTER
SETUP } to display the Router Specification Menu .
Scroll to the Number line and select the router number that you wish to patch.
{
}
Press
OUTPUT PATCH
to display the Output Patch Menu , a sample of which
is shown below.
OUTPUT PATCH
Router Output
Device ID
SP Input
Mixer Layer
SP Input is mapped to
MATRIXPRO1 Output 1
Set Device ID to NONE to define
The Router Output as an AUX.
Scroll to the Router Output line and select the specific router output number that
you want to patch.
Scroll to the SP ID line and select the physical ScreenPRO-II ID to which the
Router's output is connected.
Scroll to the SP Input line and select the physical ScreenPRO-II input to which the
router's output is connected. Please note:
~
The Mixer Layer line shows the Mixer Layer button (on the Controller)
that will be associated with the selected ScreenPRO-II input.
~
The "mapping" lines show the current output patch.
{
}
Press
ADD PATCH
to finalize the new output patch. Note that the "mapping"
lines will update accordingly.
aK==oÉãçíÉ=`çåíêçä
Using Remote Control
" section, ensure that you have written
MATRIXPRO1
7
SP 1
1
[ 1A ]
ADD
DELETE
PATCH
PATCH
N
A
V
A
D