Router Setup - Barco ScreenPRO-II User Manual

High-resolution seamless switcher
Hide thumbs Also See for ScreenPRO-II:
Table of Contents

Advertisement

oçìíÉê=pÉíìé
With your destinations properly set up, you can now set up each connected router.
Use the following procedure to set up the routers that are connected to the
ScreenPRO-II units:
1.
B
A
C
K
Figure D-8. Router Specification Menu (sample)
2.
3.
4.
ScreenPRO-II • User's Guide
Note
This procedure is not required if you are using " Internal "
source routing on your ScreenPRO-II units.
On the Encore or ScreenPRO-II Controller console, press SYSTEM > { ROUTER
SETUP } to display the Router Specification Menu .
ROUTER SPECIFICATION
Number
Name
Manufacturer
Router Type
Number of Inputs
Number of Outputs
Communication Type
COMM
DELETE
SETUP
ROUTER
Scroll to the Number line and select the router number that you wish to define.
Note
After a factory reset, two default routers are pre-assigned:
MATRIXPRO1 (MatrixPRO1 16x16 Analog) and
MATRIXPRO2 (MatrixPRO2 16x16 SDI).
If you select and assign an " EMPTY " router number, press
To continue:
~
For Barco/Folsom routers, continue with step 4 .
~
For routers from other manufacturers, continue with step 5 .
For Barco/Folsom routers, use the following steps:
Note
You may test the communication for any type of router. For
Barco/Folsom routers, the input/output fields are
automatically determined. For other manufacturers, these
fields must be set manually.
aK==oÉãçíÉ=`çåíêçä
Using Remote Control
1
[ MATRIXPRO1 ]
FOLSOM
ANALOG
16
16
ETHERNET
ADD
OUTPUT
NEW
PATCH
{
ADD NEW