2-6. Connection of Power Cord

Use the 3-core power cord that satisfies AWG 8, 250 V rated and 40 A rated or more.
Connect the power cord to the AC IN terminal block on the rear side of the projector in the following
procedure.
w
. Connection of the main power and the electric wiring work should be done by qualified electricians only.
. Do not plug the power cord into the power supply before completing all of the following connecting
operations.
1. Remove the four screws, then remove the terminal block cover.
Terminal block cover
Screws
2. Remove the screw, then remove the cable clamp.
3. Remove the screw, then remove the ground terminal.
Ground terminal
Screw
Cable clamp
Screw