4. Place a check in "ON" of HD pane.
5. Set as follows according to the field angle of contents and the screen type.
Field angle of
contents
Scope
Flat
n
The image size can be adjusted by tapping [+][_] of Size only when "Scope" is checked.

5-8-9. Brightness Adjustment

n
When the CSC adjustment is performed, the brightness changes slightly. After performing the CSC adjust-
ment, adjust the brightness again.
1. Project the test pattern (Gray10). (Refer to steps 1 to 3 in Section 5-8-1.)
2. Select an appropriate luminance level from the three levels using the Lamp Power Control pane.
n
Level 3 is the brightest level.
3. Perform the fine adjustment using [+][_].
4. Check the brightness using the luminance meter.
Screen example
Lamp Power Control pane
Control Mode Setting
In the Control Mode pane, the luminance information to be registered in the function memory is set.
. Lamp Power: The lamp power value (level and fine adjustment value) that has been set is registered in
the function memory.
. Luminance:
The luminance at that time is registered in the function memory (not the lamp power
setting value (level and fine adjustment value) that has been set). When the registered
function memory is called, the lamp power value (level and fine adjustment value) is
automatically adjusted so that the luminance becomes the same level as the luminance at
that time.
5-36 (E)
Screen type
Scope screen
Check Scope and Full Height
Check Flat and Full Height
Flat screen
Check Scope and Limited Height
Check Flat and Full Width
Control Mode pane