Intellijel Metropolix Manual page 97

Multitrack, performance-oriented pitch, gate and mod sequencer
Hide thumbs Also See for Metropolix:
Table of Contents

Advertisement

MOD Clock :
MOD :
New Stage ⎍ : Sends a trigger on the first clock pulse for each new stage that plays in the
Root :
Run ⎍ :
 
● OUTPUT ASSIGN : This parameter displays the Track number (or MOD Lane) whose signal is
sent to the A (or B ) OUT jack. It is set by 1) pressing the encoder to move the
to the OUTPUT ASSIGN parameter (highlighting it), then 2) rotating the encoder to set the source
of the signal, then 3) pressing the encoder to apply your selection.
If OUTPUT <n> ≠ 'Mod' , this parameter selects which of the two Tracks is the output source.
If OUTPUT <n> = 'Mod'' , this parameter selects which of the eight MOD lanes is the output
source.
NOTE: If you assign the Trk Out Swap parameter to a
Lane
, then any Track Assignments will "swap" when a high gate initiates the Track Out Swap
feature. For example, if you assigned a TRK 1 parameter to OUT A and TRK 2 parameter to
OUT B, then Trk Out Swap would "swap" the assignments, such that the TRK 1 parameter is
sent to OUT B; and the TRK 2 parameter is sent to OUT A.
Pulses length other than 'Auto' (as set with the LEN button), otherwise the
pulse cannot fire.
For example, a four-stage, four-pulse Linear sequence plays four
single-pulse stages (1 > 2 > 3 > 4), then resets back to Stage 1. 'Last Pulse'
would always send a trigger on the last clock pulse (Stage 4 in this case).
NOTE: Because this option is designed to trigger a reset signal before the
actual reset occurs, pressing the RESET button (or sending a trigger to the
RESET jack) will not trigger a Reset on the output (unless it happens to
coincide with the last pulse).
Outputs a clock signal derived from the MOD Lane, which you select with
the OUTPUT ASSIGN parameter.
Uses a MOD Lane as the signal source. Once you select this option, use
the OUTPUT ASSIGN parameter to select which of the eight MOD Lanes is
sent to the output.
track selected by the OUTPUT ASSIGN parameter.
Sends the Root note's pitch value (conforming to V/oct format) from the
track selected by the OUTPUT ASSIGN parameter. The Root note is set on
the SCALE screen.
Outputs a high gate (+5V) when the track selected by the OUTPUT ASSIGN
parameter is running. Output 0V when the track is stopped.
Metropolix Manual
CTRL knob
or an
AUX input or MOD
indicator next
96

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Metropolix and is the answer not in the manual?

Subscribe to Our Youtube Channel