from vertical decreases the parameter's value. Turning the knob clockwise
increases the value.
Unipolar parameters (those that are not indicated by the '±' symbol) output the
minimum parameter value when a CTRL knob is fully counterclockwise, and
the maximum parameter value when the knob is fully clockwise. For example, if
you set CTRL <n> PARAM = 'Stages Len' , then the LEN screen's STAGES
parameter is set to "1" when the CTRL 1 knob is fully CCW, and to "8" when the
knob is fully CW.
IMPORTANT: Note that unipolar CTRL functions work differently than their
corresponding AUX or MOD functions. Specifically, AUX and MOD destinations
apply an offset to the values set by the front panel, thereby modulating the
values away from their default settings. But CTRL destinations change the
default panel settings directly, as if the assigned destination had a dedicated
programming knob.
CTRL ASSIGN :
This parameter displays which Track you wish to control. To set it:
a) Press the encoder to highlight the CTRL ASSIGN field.
b) Rotate the encoder to select either TRK 1 , TRK 2 , or TRK 1+2 .
c) Press the encoder to apply your selection.