Calibrating Metropolix Outputs  
You can calibrate all four of Metropolix' variable outputs ( TRK 1 PITCH , TRK 2 PITCH , OUT A ,
OUT B ) using the same technique.
TIP : If you make a mistake at any point during the following calibration procedure, you can scroll to
the bottom of the Calibration menu, select Reload All , and press the encoder. This will reload the
current, previously saved values back into Metropolix. Once you enact a Save All , this is no longer
possible, since your edited values will overwrite the previous calibration.
To Calibrate Metropolix' Outputs:
1.
Patch the OUT A into a calibrated voltmeter with .001V accuracy.
2.
Enter Calibration Mode, as discussed earlier.
3.
Turn the encoder to highlight ' OUT A 0V: [number] ' , then press the encoder.
The [number] field is highlighted.
Turn the encoder (either clockwise or counterclockwise) to adjust the internal trim [number] until
4.
your voltmeter reads as close to 0.000V as possible, then press the encoder to lock in the
offset.
5.
Turn the encoder to highlight ' OUT A 1V: [number] ', then press the encoder.
The [number] field is highlighted.
Turn the encoder (either clockwise or counterclockwise) to adjust the internal trim [number] until
6.
your voltmeter reads as close to +1.000V as possible, then press the encoder to lock in the
offset.
7.
Patch OUT B into your voltmeter, turn the encoder to ' OUT B 0V: [number] ' and repeat Step 4,
then turn the encoder to ' OUT B 1V: [number] ' and repeat Step 6.
8.
Patch TRK 1 PITCH into your voltmeter, turn the encoder to ' Pitch 1 0V: [number] ' and repeat
Step 4, then turn the encoder to ' Pitch 1 1V: [number] ' and repeat Step 6.
9.
Patch TRK 2 PITCH into your voltmeter, turn the encoder to ' Pitch 2 0V: [number] ' and repeat
Step 4, then turn the encoder to ' Pitch 2 1V: [number] ' and repeat Step 6.
To Save the Calibration:
1.
Turn the encoder to select 'Save All' , then press the encoder to save your calibration.
 
 