SingleView
More flecxibility with any Plane, VCI plane is freely selectable. Any shape can be drawn.
Volumes can be editaed in all other visualization Modes.
Dual Format is now also possible in Render Mode and Sectional Planes Mode.
5-2-4-6
SonoAVC follicle Pro
This Feature can automatically detect follicles in a volume of an organ (e.g., ovary) and analyze their
shape and volume. From the calculated volume an average diameter can be calculated. It also lists the
objects according to their size.
Each object can be calculated automatically.
A description name can be defined for each object up to 10 descriptions. With the "Add to Report"
button all values of the measured objects can be sent to the worksheet. Also the description name
will be sent.
The description name can be edited in the worksheet.
If the number button is activated, all objects are assigned a number inside the displayed
objectaccording to the measurement index.
Group function: All objects will be added to one volume.The color of all objects will be changed to
red and the measurement will show only one result.
5-2-4-7
SonoL&D
Enhances the labor and delivery process with quantitative progression data.
5-2-4-8
TUI
TUI is a new visualization mode for 3D and 4D data sets. The data is presented as slices through the
data set which are parallel to each other. An overview image, which is orthogonal to the parallel slices,
shows which parts of the volume are displayed in the parallel planes.
This method of visualization is consistent with the way other medical systems such as CT or MRI,
present the data to the user. The distance between the different planes can be adjusted to the
requirements of the given data set. In addition it is possible to set the number of planes.
The planes and the overview image can also be printed to a DICOM printer, for easier comparison of
the ultrasound data with CT and/or MRI data.
5-2-4-9
CFM/M-CFM
NOTE:
For further details refer to the Voluson P6P8 Basic User Manual
5-2-4-10
XTD
NOTE:
For further details refer to the Voluson P6P8 Basic User Manual
5-2-4-11
Anatomical M-Mode
Anatomical M-Mode displays a distance/time plot from a cursor line, which can be defined freely.
The M-Mode display changes according to the motion of the M cursor. In the Dual format, two defined
distances can be displayed at the same time.
AMM is available in grayscale and color modes (CF, HD Flow)
5-18
6
DRAFT (M
EVISION
Section 5-2 - General Information
23, 2018)
AY
V
™ P8 / V
OLUSON
OLUSON
B
S
M
ASIC
ERVICE
™ P6
ANUAL

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Voluson p6 bt165670023567002456699995670021

Table of Contents