2.5.7 Serial port configuration commands
The ATTO FibreBridge serial ports are configured with default settings but may be customized to your
specifications using the CLI commands in this section.
SerialPortBaudRate
Configures/reports the baud rate for the FibreBridge RS-
232 serial port. The number of data bits per character is
fixed at 8 with no parity. Choices are 2400, 9600, 19200,
38400, 57600 and 11520
Default: 9600
FibreBridge 2400 default: 11520
Set syntax: set SerialPortBaudRate [2400 | 9600 |19200
|38400 | 57600 |115200]
Requires a SaveConfiguration command
Get syntax: get SerialPortBaudRate
SerialPortEcho
Enables/disables/reports the echoing of keyboard input.
When enabled, all non-control character keyboard input
is output to the display. Local ASCII terminal (or terminal
emulator) echo settings should be set to disabled while
using SerialPortEcho enabled
Default: disabled
FibreBridge 2400 default: enabled
Set syntax: set SerialPortEcho [enabled | disabled]
Requires a SaveConfiguration Restart command
Get syntax: get SerialPortEcho
SerialPortStopBits
Configures/reports the number of stop bits per character
for the FibreBridge RS -232 serial port. The number of
data bits per character is fixed at 8 with no parity.Choices
are 1 or 2.
Default: 1
Set syntax: set SerialPortStopBits [1 | 2]
Requires a SaveConfiguration command
Get syntax: get SerialPortStopBits